105
Installing and
connection of
three ow meters
1. Attach the third ow meter to the
water outlet connections by quick
coupling.
2. Connect the third ow meter as shown in the following picture:
a. Disconnect the cable from ow meter 1 (connections are marked 1 and 2)
b. Connect the T-splitter of ow meter 3 to the Y-splitter.
c. Connect the cable of ow meter 3 to the T-splitter from below.
d. Plug the cable of ow meter 1 into the right-hand connection of the T-splitter.
Connection cable of ow meter 2
T-splitter
Y-splitter
Connection cable of ow meter 1
Connection cable of ow meter 3