Parameterisation of the ow meter
1. Press the S button for 2 seconds.
The operator panel switches into the Function
selection mode.
1. Initial situation: The screen for setting the reversed
output is displayed, the lower line ashes.
2. Press one of the ARROW buttons, until the upper line
shows F1.
3. Press the S button, to enter the lower line.
6. The screen for setting the reversed output appears
on the display.
Continue parameterisation with the next section “Se-
lection of reversed output”.
4. Choose HYS with the ARROW buttons.
5. Press the S button, to conrm the choosen setting.
Basic setting
Selection of
output mode
Selection of
reversed output
The basic setting of the control unit is the measurement mode. In this mode, the ow is
detected and the switching function is in operation.
IMPORTANT! If no button is pressed for 30 seconds during the change of a setting,
the display will start ashing. This is to prevent from incomplete settings, in case of the
operator should leave the machine during setting process.
The following settings are available:
HYS Hysteresis mode
WIN Window comparator mode
ACCUMU Accumulated output mode
PLS Accumulated pulse output mode
The following settings are available:
I_P Normaler output
I_N Reversed output
2. Choose I_N (reversed output) with the ARROW buttons.
3. Press the S button, to conrm the choosen setting.
4. The screen for entering the set values is shown on
the display.
Continue parameterisation with the next section “In-
put of set values”.