EasyManua.ls Logo

Fronius CU 1800 - Transport; Safety

Fronius CU 1800
146 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85
Transport
Safety
Transport
1. Release the locking levers of the front rollers.
2. For moving the water chiller:
(a) hold it on the side handles (both
sides), or
(b) on the top edge of the backside.
IMPORTANT! Pressure on the cov-
ers will cause excessive pressure
on the pipes and internal compo-
nents. This can lead to deformation
or malfunction (media leakage).
CAUTION!
Danger of compressor failure due to leaking compressor oil!
Do not install or place the water chiller diagonally. Compressor oil can leak and get into
the refrigerant lines.
- Place the water chiller only in horizontal position.
(a)
(b)
(a)

Table of Contents