Parameterisation: General functions
Main menü The following parameters are displayed in the main menu:
- Temperature and setting temperature of the cooling liquid
- Discharge pressure of the cooling liquid
IMPORTANT! The single parameters can be scrolled through with the SEL button.
Start screen:
Value PV: Actual inlet temperature of the cooling liquid
Value SV: Set temperature of the cooling liquid
Discharge pressure:
Value PV: Parameter code
Value SV: Inlet pressure of cooling liquid
- Set temperature can be changed with the ARROW buttons.
- The set value ashes during the change.
- To save the changed value, press the SEL button.
IMPORTANT! If the SEL button is not pressed, the changed value is reset to the primary
value after 3 seconds.
Monitoring menu
Cooling liquid outlet temperature:
Value PV: Parameter code
Value SV: Temperature of the cooling liquid at the inlet, from which it
is supplied to the device of the customer.
Cooling liquid inlet temperature:
Value PV: Parameter code
Value SV: Outlet temperature of the cooling liquid.
Access the monitoring menu:
Press the button MENÜ and hold it for 2 seconds.
Scrolling to the next parameter:
The operator can scroll through all parameters in sequence with the SEL button.
Temperature of refrigerant circuit compressor inlet:
Value PV: Parameter code
Value SV: Temperature at compressor inlet of refridgeration circuit.