Code Description Behaviour Remedy
517
Power derating caused by
too high a temperature
When power derat-
ing occurs, a warning
message is shown on
the display.
If necessary, purge cooling air
openings and heat sink;
fault is rectified automatically;
**)
518 Internal DSP malfunction Warning message on
the display
*)
519 No communication pos-
sible with the storage unit
Storage unit warning
message
*)
520
No energy fed into the grid
by MPPT1 in the past 24
hours
Warning message is
shown on the display
Acknowledge status code;
check whether all the conditions
for the problem-free feeding of
energy into the grid have been
met (e.g. are the solar modules
covered with snow?); *)
522 DC low String 1 Warning message on
the display
*)
523 DC low String 2
558,
559
Functional incompatibility
(one or more PC boards in
the inverter are not com-
patible with each other,
e.g. after a PC board has
been replaced)
Warning message on
the display
Update inverter firmware; *)
560
Power derating caused by
overfrequency
Displayed when grid
frequency becomes
excessively high. The
power is reduced.
As soon as the grid frequency is
back within the permissible
range and the inverter has re-
turned to normal operation, the
fault is rectified automatically;
**)
564 Functional incompatibility
(one or more PC boards in
the inverter are not com-
patible with each other,
e.g. after a PC board has
been replaced)
Warning message on
the display
Update inverter firmware; *)
566
Arc detector switched off
(e.g. during external arc
monitoring)
The status code is
displayed every day
until the arc detect-
or is reactivated.
No error
Confirm status code by pressing
'Enter'
568
Incorrect input signal on
the multifunction current
interface
The status code is
displayed in the case
of an incorrect input
signal on the multi-
function current in-
terface and with the
following setting:
Basic menu / Input
signal / Mode of op-
eration = Ext. Signal,
triggering method =
Warning
Acknowledge status code;
check the devices connected to
the multifunction current inter-
face; **)
572 Power limited by the
power stage set
Power is being lim-
ited by the power
stage set
*)
107
EN

Table of Contents

Other manuals for Fronius Symo Advanced 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced 10.0-3-M and is the answer not in the manual?

Fronius Symo Advanced 10.0-3-M Specifications

General IconGeneral
AC nominal output10.0 kW
Max. efficiency98.1%
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP66
Max. output current14.5 A
THD< 3%
Max. input voltage1000 V
Operating temperature range-25°C - +60°C
Max. apparent AC power10 kVA
AC nominal voltage400 V
Power factor (cos φac,r)1
DC max. power15, 000 W
Warranty5 years
CoolingFan