3 4
Installing the
Datamanager in
the inverter
WARNING!
Danger of residual voltage from capacitors.
This may result in an electric shock.
Wait for the capacitors to discharge. The discharge time is five minutes.
WARNING!
Danger from inadequate ground conductor connection.
This can result in serious injury and damage to property.
The housing screws provide a suitable ground conductor connection for
earthing the housing and must NOT be replaced by any other screws that do
not provide a reliable ground conductor connection.
IMPORTANT! Observe the ESD guidelines when handling option cards.
IMPORTANT! Only one Fronius Datamanager in master mode is permitted per
Fronius Solar Net ring. Switch any other Fronius Datamanagers to slave mode or
remove them.
Seal off the unoccupied option card slot by replacing the cover (item number
42,0405,2094); alternatively, use an inverter without a Fronius Datamanager
(light version).
IMPORTANT! Only break out one
opening for the PC board when in-
stalling a Datamanager in the inverter.
59
EN

Table of Contents

Other manuals for Fronius Symo Advanced 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced 10.0-3-M and is the answer not in the manual?

Fronius Symo Advanced 10.0-3-M Specifications

General IconGeneral
AC nominal output10.0 kW
Max. efficiency98.1%
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP66
Max. output current14.5 A
THD< 3%
Max. input voltage1000 V
Operating temperature range-25°C - +60°C
Max. apparent AC power10 kVA
AC nominal voltage400 V
Power factor (cos φac,r)1
DC max. power15, 000 W
Warranty5 years
CoolingFan