Code Description Behaviour Remedy
781 -
794
Provides information
about the internal pro-
cessor status
Warning message on the
display
*)
*) If the status code is displayed all the time: Notify a Fronius-trained service
technician
Class 10 - 12
status codes
1000 - 1299- Provide information on the status of the internal processor pro-
gram
Description Is of no concern when the inverter is working properly
and only appears in the "Status PS" setup parameter. In
the event of an actual error, this status code assists
Fronius Technical Support during the error analysis.
Customer ser-
vice
IMPORTANT! Contact your Fronius dealer or a Fronius-trained service techni-
cian if
-
an error appears frequently or all the time
-
an error appears that is not listed in the tables
Operation in
dusty environ-
ments
When operating the inverter in extremely dusty environments:
when necessary, clean the cooling elements and fan on the back of the inverter
as well as the air intakes at the mounting bracket using clean compressed air.
111
EN

Table of Contents

Other manuals for Fronius Symo Advanced 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced 10.0-3-M and is the answer not in the manual?

Fronius Symo Advanced 10.0-3-M Specifications

General IconGeneral
AC nominal output10.0 kW
Max. efficiency98.1%
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP66
Max. output current14.5 A
THD< 3%
Max. input voltage1000 V
Operating temperature range-25°C - +60°C
Max. apparent AC power10 kVA
AC nominal voltage400 V
Power factor (cos φac,r)1
DC max. power15, 000 W
Warranty5 years
CoolingFan

Related product manuals