Code Description Behaviour Remedy
740 Initialisation error - error
in file system on USB flash
drive
Warning message on the
display
Check USB flash drive; re-
format on PC for FAT12,
FAT16 or FAT32
741 Error during recording of
logging data
Warning message on the
display
Remove and then reinsert
USB flash drive; check or re-
place USB flash drive
743
Error occurred during up-
date process
Warning message on the
display
Repeat update process,
check USB flash drive; *)
745 Update file corrupt
Warning message on the
display, update process
is interrupted
Download update file again;
check or replace USB flash
drive; *)
746
Error occurred during up-
date process
Warning message on the
display, update process
is interrupted
Wait for two minutes, then
start the update again; *)
751 Time lost
Warning message on the
display
Reset time and date on the
inverter; *)
752
Real Time Clock module
communication error
753
Internal error: Real Time
Clock module is in emer-
gency mode
Time may be inaccurate
or lost (feeding energy
into the grid normal)
Reset time and date on the
inverter
754 -
755
Provides information
about the internal pro-
cessor status
Warning message on the
display
*)
757 Hardware error in the Real
Time Clock module
Error message on the
display; the inverter is
not feeding any energy
into the grid
*)
758 Internal error: Real Time
Clock module is in emer-
gency mode
Time may be inaccurate
or lost (feeding energy
into the grid normal)
Reset time and date on the
inverter
760 Internal hardware error Error message on the
display
*)
761 -
765
Provides information
about the internal pro-
cessor status
Warning message on the
display
*)
766
Emergency power limita-
tion has been activated
(max. 750 W)
Error message on the
display
767
Provides information
about the internal pro-
cessor status
Warning message on the
display
*)
768
Different power limitation
in the hardware modules
772 Storage unit not available
773
Software update group 0
(invalid country setup)
775
PMC power stage set not
available
Warning message on the
display
Press 'Enter' key to acknow-
ledge error; *)
776 Invalid device type
110

Table of Contents

Other manuals for Fronius Symo Advanced 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo Advanced 10.0-3-M and is the answer not in the manual?

Fronius Symo Advanced 10.0-3-M Specifications

General IconGeneral
AC nominal output10.0 kW
Max. efficiency98.1%
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP66
Max. output current14.5 A
THD< 3%
Max. input voltage1000 V
Operating temperature range-25°C - +60°C
Max. apparent AC power10 kVA
AC nominal voltage400 V
Power factor (cos φac,r)1
DC max. power15, 000 W
Warranty5 years
CoolingFan