The connection is established.
Access point:
The inverter serves as an access point. A PC or smart device connects directly
with the inverter. It is not possible to connect to the internet. The "Network
name (SSID)" and "Network key (PSK)" can be assigned in this menu.
It is possible to operate a connection via WLAN and via access point simultan-
eously.
Modbus Modbus RTU interface 0 / 1
If one of the two Modbus RTU interfaces is set to Slave, the following input fields
are available:
"Baud rate"
The baud rate influences the transmission speed between the individual compon-
ents connected in the system. When selecting the baud rate, ensure that it is the
same at both the sending and receiving end.
"Parity"
The parity bit can be used to check the parity. It detects transmission errors. A
parity bit can safeguard a specific number of bits. The value (0 or 1) of the parity
bit must be calculated by the sender and is checked by the recipient using the
same calculation. The parity bit can be calculated for even and odd parity.
"SunSpec Model Type"
Depending on the SunSpec model, there are two different settings.
float: SunSpec Inverter Model 111, 112, 113 or 211, 212, 213.
int + SF: SunSpec Inverter Model 101, 102, 103 or 201, 202, 203.
"Meter address"
The value entered is the identification number (Unit ID) assigned to the
meter.Can be found on the user interface of the inverter in the “Communication
“Modbus” menu.
Factory setting: 200
"Meter address"
The value entered is the identification number (Unit ID) assigned to the meter.
Can be found on the user interface of the inverter in the “Communication
“Modbus” menu.
Factory setting: 1
Slave as Modbus TCP
If the function "Slave as Modbus TCP" is activated, the following input fields are
available:
"Modbus port"
Number of the TCP port that is to be used for Modbus communication.
"SunSpec Model Type"
Depending on the SunSpec model, there are two different settings.
float: SunSpec Inverter Model 111, 112, 113 or 211, 212, 213.
int + SF: SunSpec Inverter Model 101, 102, 103 or 201, 202, 203.
100

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo GEN24 3.0 and is the answer not in the manual?

Fronius Symo GEN24 3.0 Specifications

General IconGeneral
CategoryInverter
Output Power3.0 kW
Protection RatingIP66
Max. apparent AC power3.0 kVA
THD< 3 %
Number of MPP trackers2
Max. DC power4.5 kW
ModelSymo GEN24 3.0
Communication InterfacesEthernet, Wi-Fi
AC grid connectionSingle-phase
Battery voltage range40 V - 56 V
Max. charging / discharging power3 kW
Operating Temperature Range-25°C - +60°C