The Fronius GEN24 inverter is a grid-connected inverter with a backup power
function – it is not a stand-alone inverter. The following restrictions must there-
fore be observed in backup power mode:
-
Backup power mode may be in operation for at max. 2000 hours
-
Backup power mode may be in operation for more than 2000 operating hours
if 20% of the duration of the inverter's grid power feed operation is not ex-
ceeded at the relevant time.
* Depending on the device variant, suitable battery, appropriate wiring, set-
tings, and local standards and guidelines.
Thermal concept Ambient air is drawn in by the fan on
the front side and blown out at the
device sides. The even heat dissipation
allows several inverters to be installed
next to each other.
NOTE!
Risk due to insufficient cooling of the inverter.
This may result in a loss of power in the inverter.
Do not block the fan (for example, with objects that protrude through the
touch guard).
Do not cover the ventilation slots, even partially.
Make sure that the ambient air can always flow through the inverter's ventila-
tion slots unimpeded.
Fronius Sol-
ar.web
With Fronius Solar.web or Fronius Solar.web Premium, the PV system can be
easily monitored and analysed by the system owner and installer. If configured
accordingly, the inverter transmits data such as power, yields, load, and energy
balance to Fronius Solar.web. For more information see Solar.web - monitoring &
analysis.
Configuration is carried out via the setup wizard, see chapter Installation with
the app on page 78 or Installation using the web browser on page 78.
Prerequisites for configuration:
-
Internet connection (download: min. 512 kBit/s, upload: min. 256 kBit/s)*.
-
User account on solarweb.com.
-
Completed configuration via the setup wizard.
* The information given does not constitute an absolute guarantee of fault-
less function. High error rates in the transmission, reception fluctuations
or transmission drop-outs can have a negative effect on the data transfer.
15
EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo GEN24 3.0 and is the answer not in the manual?

Fronius Symo GEN24 3.0 Specifications

General IconGeneral
CategoryInverter
Output Power3.0 kW
Protection RatingIP66
Max. apparent AC power3.0 kVA
THD< 3 %
Number of MPP trackers2
Max. DC power4.5 kW
ModelSymo GEN24 3.0
Communication InterfacesEthernet, Wi-Fi
AC grid connectionSingle-phase
Battery voltage range40 V - 56 V
Max. charging / discharging power3 kW
Operating Temperature Range-25°C - +60°C