Technical data
Fronius Symo
GEN24 3.0 / 3.0
Plus
DC input data
MPP voltage range
(at rated power)
125 - 800 V
Max. connected load (P
PV max
)
Total
PV 1
PV 2
4500 Wp
4500 Wp
4500 Wp
Max. processable PV power
Total
PV 1
PV 2
3150 Wp
3150 Wp
3150 Wp
Max. input voltage
at 1000 W/m²/-10 °C in an open cir-
cuit
1000 V
Feed-in start-up input voltage in grid
operation
5)
80 V
Max. input current
PV 1
PV 2
12.5 A
12.5 A
Max. short circuit current of module
array (I
SC PV
)
PV 1
PV 2
20 A
20 A
Max. total short circuit current of
module array
(I
SC PV1
+ I
SC PV2
= I
SC max
) 40 A
Max. inverter backfeed current to the
array
3)
PV 1
PV 2
20 A
20 A
Number of inputs - PV 1 2
Number of inputs - PV 2 1
Max. capacity of the module array
against earth
600 nF
Insulation resistance test limit value
between module array and earth (on
delivery)
8)
100 kΩ
Adjustable range of insulation resist-
ance test between module array and
earth
7)
10 - 10,000 k
Limit value and tripping time of the
sudden residual current monitoring
(on delivery)
30 / 300 mA / ms
60 / 150 mA / ms
90 / 40 mA / ms
Limit value and tripping time of the
continuous residual current monitor-
ing (on delivery)
300 / 300 mA / ms