Fronius Symo GEN24
Device concept The inverter transforms the direct current generated by the solar modules into
alternating current. This alternating current is fed into the public grid and syn-
chronized with the grid voltage in use. Moreover, the solar energy can also be
stored in a connected battery for later use.
The inverter is intended for use in grid-connected photovoltaic systems. The in-
verter has a backup power function and switches to backup power mode if it has
been wired accordingly*.
The inverter automatically monitors the public grid. Whenever conditions in the
electric grid are inconsistent with standard conditions (for example, grid switch-
off, interruption), the inverter will immediately stop producing power and inter-
rupt the supply of power into the grid.
The grid is monitored by monitoring the voltage, frequency and islanding condi-
tions.
After installation and commissioning, the inverter's operation is fully automatic;
the inverter draws the maximum possible power from the PV modules.
Depending on the operating point, this power is used in the home, stored in a bat-
tery* or fed into the grid.
As soon as the energy provided by the PV modules is no longer sufficient, the
power from the battery is fed into the home. Depending on the setting, power
may also be obtained from the public grid in order to charge the battery*.
When its temperature gets too high, the inverter automatically reduces the out-
put or charging power, or switches off completely, in order to protect itself.
Reasons for the temperature being too high include a high ambient temperature
or insufficient heat dissipation (for example, inadequate heat dissipation when in-
stalled in switch cabinets).
* Depending on the device variant, suitable battery, appropriate wiring, set-
tings and local standards and guidelines.
Function over-
view
Function Symo GEN24 Symo GEN24 Plus
Backup power variant - PV Point
(OP)
Battery connection*
Available as an op-
tion**
Backup power variant - Full Backup
* For suitable batteries, see chapter Suitable batteries.
** The functions are optionally available via Fronius UP (see chapter Fronius
UP).
13
EN

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo GEN24 3.0 and is the answer not in the manual?

Fronius Symo GEN24 3.0 Specifications

General IconGeneral
CategoryInverter
Output Power3.0 kW
Protection RatingIP66
Max. apparent AC power3.0 kVA
THD< 3 %
Number of MPP trackers2
Max. DC power4.5 kW
ModelSymo GEN24 3.0
Communication InterfacesEthernet, Wi-Fi
AC grid connectionSingle-phase
Battery voltage range40 V - 56 V
Max. charging / discharging power3 kW
Operating Temperature Range-25°C - +60°C