EasyManua.ls Logo

Fronius Symo GEN24 3.0

Fronius Symo GEN24 3.0
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC input/output data
Current (inrush)
6)
9.9 A / 4 ms
Nominal frequency
50 / 60 Hz
1)
Initial short circuit alternating cur-
rent / phase I
K
8 A
Total harmonic distortion < 3.5%
Power factor cos phi
2)
0 - 1 (adjustable)
0.7 - 1 (recommended)
Max. permitted mains impedance Z
max
at PCC
4)
None
Maximum output fault current / dura-
tion
7.5 A / 157 ms
AC output data PV Point
Max. output power 4133 W (for 5 s)
Rated power 3000 W
Nominal output current 13 A
Nominal mains voltage 1 ~ NPE 220 V / 230 V / 240 V
Nominal frequency
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
General data
Maximum efficiency 98.2%
European efficiency (U
mpp nom
) 97%
European efficiency (U
mpp max
) 96.6%
European efficiency (U
mpp min
) 95.8%
Self-consumption at night < 10 W
Cooling Controlled forced-air ventilation
Protection class IP 66
Dimensions H x W x D 530 x 474 x 165 mm
Weight 16.5 kg
Inverter topology Non-insulated transformerless
Permitted ambient temperature -25 °C – +60 °C
Permissible humidity 0–100% (incl. condensation)
EMC device class B
DC/AC overvoltage category
(in accordance with IEC 62109-1)
2/3
Pollution degree 2
Sound pressure 36 dB(A)
Safety class (according to IEC62103) 1
149
EN

Table of Contents

Related product manuals