Example: Battery system without photovoltaics, including second producer in
the house
Second producer in home network 2000 W
Target value set at feed-in point 0 W
Infeed into the public grid 0 W
Consumption in home 500 W
TARGET: 0W
0 W
500 W
2000 W
1500 W
1500 W
+
-
00
1
Example: Battery system including second producer in the house
PV system available power 1000 W
Power into the battery 2500 W
Power consumption (AC) of the inverter 1500 W
Second producer in home network 2000 W
Target value set at feed-in point 0 W
Infeed into the public grid 0 W
Consumption in home 500 W
TARGET: 0W
0 W
500 W
2000 W1000 W
2500 W
1500 W
Example: Battery system including second producer in the house (with AC
max. limitation)
PV system available power 1000 W
91