99
EN
Changing earth current watchdog
1. Remove side panels
2. Loosen two screws (2) on earth
current watchdog (1)
Removing earth
current watch-
dog
1. Loosen screw (3) on luster terminal
2. Remove lead (4)
Fig. 1 Removing earth current watchdog
Fig. 2 Loosening luster terminal on earth current
watchdog
Fig. 3 Removing fan and exposing watchdog cable
1. Remove fan sheet (5) (including fan)
2. Cut through the cable ties on watchdog cable (6)
(5) (6)
(3)
(4)
(1)
(2)