113
EN
Changing intermediate circuit capacitors (TS 4000/
5000, TPS 3200/4000/5000)
1. Remove side panels
2. Loosen three screws (1) on rear of
housing (2)
3. Remove rear of housing (2)
Removing inter-
mediate circuit
capacitors
1. Loosen two screws (3) on cover
sheet (4)
2. Remove cover sheet (4)
Fig. 1 Removing rear of housing
(1)
(1)
(2)
Fig. 2 Removing cover sheet
1. Loosen four capacitor screws (5)
NOTE! When loosening capacitor nuts (6) - Fig.4 - hold the capacitors (7) -
Fig.3 - in place.
2. Loosen two capacitor nuts (6)
3. Remove capacitors (7)
(3) (3)
(4)
Fig. 3 Loosening capacitor screws
(5)
(5)
Fig. 4 Loosening capacitor nuts
(7)
(6)