EasyManua.ls Logo

Fronius TransSynergic 5000 - Corrections During Welding

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100
1. Insert leads (8) and (9) of the watch-
dog cable (6) into the following pins
on the 24-pin Molex plug (7):
- X4:10
- X4:22
2. Plug 24-pin Molex plug (7) into
UST:X4 PC board
Fitting earth
current watch-
dog
1. Unplug 24-pin Molex plug (7) from
UST:X4 PC board
2. Remove leads (8) and (9) of the
watchdog cable (6) from the following
pins on the 24-pin Molex plug (7):
- X4:10
- X4:22
- Use Molex extractor tool
Fig. 4 Detaching watchdog cable
Removing earth
current watch-
dog
(continued)
Fig.5 Connecting watchdog cable
Fig.6 Fixing watchdog cable in place and fitting fan
(5) (6)
1. Fix watchdog cable (6) using cable ties
2. Fit fan sheet (5) (including fan)
(9) (8)
(7)
(6)
(9) (8)
(7)
(6)

Table of Contents

Other manuals for Fronius TransSynergic 5000

Related product manuals