EasyManua.ls Logo

Fronius TransSynergic 5000 - Plug Layout; Measuring Points

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
Plug layout
Fig.71 Connections on the primary rectifier
TPS 2700
Fig.72 Connections on the primary rectifier
TS 4000/5000, TPS 3200/4000/5000
L1
L2
(-)
(+)
L1
L2
L3
(-)
(+)
Pin function
L1 Mains voltage input L1
L2 Mains voltage input L2
L3 Mains voltage input L3
(+) Intermediate circuit voltage output +
(-) Intermediate circuit voltage output -
L3
Measuring points
Fig.73 Measuring points on primary rectifier TPS
2700
Fig.74 Measuring points on primary rectifier TS
4000/5000, TPS 3200/4000/5000
Measurement on each of the diode regions must produce a result of 0.4 V.