EasyManua.ls Logo

Fronius TransSynergic 5000 - Fitting Transformer

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
111
EN
Fitting transfor-
mer
1. Push insulators (15) onto secondary
connections
2. Wind both of the middle primary leads
twice around the ferrite core and
fasten with cable tie (14)
Fig.5 Fastening insulators and ferrite core
(14)(15)
(15)
Before fitting the transformer, arrange the
primary leads as follows:
1. Feed the „blue lead“ through the
upper sensor (16)
2. Feed the „orange lead“ through the
lower sensor (17)
1. Fit transformer holder (12), including
transformer (13), using four screws (11)
Fig.6 Feeding primary leads through sensors
(16)
(17)
(11)
(13) (12)
Fig. 7 Fitting transformer
1. Fit throttle lead (10) to middle tap
connection using screw (9)
2. Fit copper clips (7) and (8)
(7)
(8)
(9)
(10)
Fig. 8 Connecting transformer 1