EasyManua.ls Logo

Fronius TransSynergic 5000 - Changing Throttle (TS 4000;5000, TPS 3200;4000;5000); Removing Throttle

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92
Fig. 1 Preparing throttle lead for removal
(2)(3)
(4)
(5)
Fig. 2 Removing throttle lead
Fig. 3 Removing front of the housing
1. Remove side panels
2. On the minus socket, loosen hexagon
bolt (1) using a size 19 spanner
- Feed out the throttle lead (2) from the
shunt (3)
1. On the transformer, loosen hexagon
nut (4) using a size 13 spanner
2. Remove protective element (5) and
throttle lead (2)
1. Remove screw (6) from the front of
the housing:
NOTE! When removing the
control panel (7), take care not to
bend, stretch or strain the ribbon
cable connected to it.
2. Carefully swivel out the control panel
(7) and unplug the ribbon cable
Changing throttle (TS 4000/5000, TPS 3200/4000/5000)
Removing throttle
(1)
(6)
(6)
(6)
(7)
(2)