EasyManua.ls Logo

Fronius TransSynergic 5000 - Nothing Happens on Control Panel (TPS 3200;4000;5000)

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Nothing happens
on control panel
(TPS 3200/4000/
5000)
Start
3x230V/3x400V on
the terminal strip X7/5
- X7/7 OK?
Check mains cable,
line filter and supply
voltage
No
Voltage on intermedi-
ate circuits 1 and 2 >
200V DC?
Change primary
rectifier
Mains switch/cabling
OK?
Check/change mains
switch and cabling
Change BPS
Steady +24V int/ext
LEDs on UST?
Switch power source
off, unplug plug X3
from UST, switch
power source on
Change NT 24
Yes
Yes
Steady +24V int/ext
LEDs on NT 24?
Switch power source
off, plug X3 plug into
UST and unplug X7,
switch power source
on
No
Yes
No
Yes
No
Yes
A
Voltage present on 2
phases of rectifier
V1?
Yes
No
LED 230V flashing on
ASU 40 at U
nom
230V?
Change ASU 40
No
Yes
MV power sources
with U
nom
230V
No
No
B

Table of Contents

Other manuals for Fronius TransSynergic 5000

Related product manuals