EasyManua.ls Logo

Fronius TransSynergic 5000 - Function Overview; Plug Layout

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41
EN
Function over-
view
Plug layout
Pin Function
X1 Connection to cooling unit
Fig.7 Plug and connections on ASU 27 PC board
(X6)
(X5)
(X4)
(X1)
(X3)
(X2)
Pin 1 NC
Pin 2 230/400 V from
primary rectifier
Pin 3 NC
Pin 4 Cooler 400 V
Pin 5 NC
Pin 6 Cooler 230 V
Pin 7 NC
Pin 8 NC
Pin 9 NC
Pin 10 NC
Pin 11 NC
Pin 12 NC
Pin 13 NC
Pin 14 NC
Pin 15 NC
Pin 16 NC
- For switching between 230 V AC and 400 V AC
- For generating control voltage +12 V and +5 V from the input voltage
- When switching on, the switching mechanism on the PC board detects the input
voltage:
a) With an input voltage of 400 V AC, the ASU 27 PC board switches both power
modules on BPS 25/BPT 27 in series
b) With an input voltage of 230 V AC, the ASU 27 PC board switches both power
modules on BPS 25/BPT 27 in parallel.
X2 not connected
X3 Connection to BPS 25/BPT 27 PC board (intermediate circuit 1+)
X4 Connection to BPS 25/BPT 27 PC board (intermediate circuit 1-)
X5 Connection to BPS 25/BPT 27 PC board (intermediate circuit 2+)
X6 Connection to BPS 25/BPT 27 PC board (intermediate circuit 2-)