26
Service code Err
50
Start
Does service code Err
50 appear directly
after switching on,
although the primary
power module is not
operating?
Yes
Imbalance in interme-
diate circuit > 35V?
+5V available on UST
from X6/26 - X7/8?
No
Yes
Change BPS
Yes
Does Err 50 disappear
after a short while?
Yes
No
Change intermediate
circuit electrolytic
capacitors
Switch off power
source; unplug X2
from NT 60; switch on
power source
Err 50?
Change NT 60
No
Yes
Switch off power
source; discharge
intermediate circuit
electrolytic capacitors;
unplug X1 from NT 24;
switch on power source
Imbalance in interme-
diate circuit > 35V?
No
Change NT 24
A
Select „Rod electro-
de“ mode
On the BPS, the
brightness of the
control LEDs remains
unchanged when the
BPS is accessed
Change UST
No
Yes
No
Change UST
Yes