EasyManua.ls Logo

Fronius TransSynergic 5000 - Connecting the Mains Cable

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
75
EN
LED checklist
Measuring points
There are no LED indicators on PC board NF 3400 or line filters 40 A/80 A.
There are no measuring points on PC board NF 3400 or line filters 40 A/80 A.
Plug layout line
filter 40 A/80 A
Line filter 40 A
Fig. 49 Connections on line filter 40 A and 80 A
Line filter 80 A
Pin Function
X1 Mains supply
U1 L1 in
V1 L2 in
W1 L3 in
PE PE conductor
X2 Connection to BPS 42/50/53
U2 L1 out
V2 L2 out
W2 L3 out
X3 Earth current watchdog
X4 Connection to ASU 40 (on line filter 80 A only)
U2 L1 out
V2 L2 out
W2 L3 out
X1
X3
X2 X1
X3
X2 X4