Changing transformer (TS 4000/5000, TPS 3200/4000/
5000)
1. Remove side panels
2. On BPS 42/50 PC board, loosen 4
screws (1) for primary transformer
leads
3. Remove protective elements (2)
1. Cut open cable tie on toroidal tape
cores (3) and (4)
Important! If necessary, cut open any
other cable ties near the toroidal tape
cores as well.
Removing trans-
former
(1)
(1)
(2)
(2)
Fig. 1 Removing transformer leads
Fig. 2 Loosening toroidal tape cores
(3)
1. Feed primary transformer leads „1+“
and „2+“ out through toroidal tape
cores (3) and (4)
2. Feed all primary transformer leads
through bushing (6)
Fig. 3 Feeding transformer leads
(4)
(4)
(3)
(6)