EcF | xxx (code no.32)
Cause: BPS configuration fault, x stands for:
1 TPS 2700 with incorrect power module
2 TS/TPS/TP 4000 with incorrect power module
3 TS/TPS/TP 5000 with incorrect power module
4 TT 2200, MW 2200 with incorrect primary power module
5 MW 1700 with incorrect primary power module
253 This configuration functions only from UST2A V1.3 A onwards
254 This configuration functions only from UST PC board, version
UST2A onwards
255 Unknown primary power module
Remedy: Fit correct primary power module
EFD | xx.y (code no.30)
Cause: Fault in wirefeed system, xx and y emanate from the list of service codes
for the wirefeed system.
Remedy: check wirefeed system
EIF | xx.y (code no.63)
Cause: fault connected with a robot interface, xx and y emanate from the list of
service codes of your robot interface.
Remedy: check robot interface, update software, change robot interface
Err | Arc (code no.61)
Cause: DPS 5000 only: DPS detected arc formation
Remedy: check application
Err | bPS (code no.18)
Cause: DSP displays internal fault
Remedy: update software. Change UST2 PC board. Change BPS PC board.
Err | Cfg (code no.72)
Cause: Power source configuration changed (e.g. connected in parallel with a
second power source)
Remedy: dismiss service code by pressing set-up button
Err | EPF (code no.22)
Cause: Fault during charging of flex
Remedy: update software. Change UST2 PC board.
Err | IP (code no.19)
Cause: DSP displays primary overcurrent
Remedy: check secondary power module. Change primary power module.
Err | Jo (code no.67)
Cause: JobMaster temperature sensor faulty
Remedy: change JobMaster welding torch
Err | Lic (code no.40)
Cause: faulty/incorrect licence key
Remedy: check licence key. Check and update enable codes. Check/change earth
current watchdog