Err | 059 (code no.59)
Cause: overvoltage in the secondary circuit: safety cut-out has tripped
Remedy: check secondary circuit, including TP4CEL40
Err | 060 (code no.60)
Cause: DPS5000 only: Due to an opened door contact, SITRE1A has triggered
safety disconnection
Remedy: safety cut-out: close door contact
Err | 062 (code no.62)
Cause: Remote control TP08 overtemperature
Remedy: allow TP08 to cool down. Change TP08.
Err | 068 (code no.68)
Cause: secondary circuit safety cut-out has tripped
Remedy: change TTS PC board
Err | 069 (code no.69)
Cause: illegal change of mode or process during welding
Remedy: reignite arc
Err | 073 (code no.73)
Cause: no communication between power source and remote control RCU 5000i
Remedy: check LocalNet leads. Check software version (UST 3.21.4). Wait for
software update to finish.
Err | 23.x (code no.23)
Cause: config memory (CFM) fault on UST2B PC board, x stands for:
1 config memory not found
2 checksum error
3 CFM undescribed
5 unknown PC board type
8 invalid identifier (identifier UST1 to UST2)
Remedy: update software. Change UST2B PC board.
Err | 24.x (code no.24)
Cause: config memory (CFM) fault on BPS PC board, x stands for:
1 config memory not found
2 checksum error
3 CFM undescribed
5 unknown PC board type
8 invalid identifier (identifier UST1 to UST2)
Remedy: check ribbon cable. Change BPS PC board.
Err | 25.x (code no.25)
Cause: config memory (CFM) „alternator“ fault, x stands for:
1 config memory not found
2 checksum error
3 never tested
4 test was not OK
5 unknown PC board type
8 invalid identifier (identifier UST1 to UST2)
Remedy: change TTS