51
EN
Measuring points Plug/pin Measuring result command
value
Intermediate circuit voltage 1 M1/TP1-TP3 320 V DC
Intermediate circuit voltage 2 M2/TP5-TP7 320 V DC
Diode check module M1 M1/TP1-TP2 (+) 0.46 V
M1/TP1-TP4 (+) 0.46 V
M1/TP3 (+) - TP2 0.46 V
M1/TP3 (+) - TP4 0.46 V
Diode check module M2 M2/TP5-TP6 (+) 0.46 V
M2/TP5-TP8 (+) 0.46 V
M2/TP7 (+) - TP6 0.46 V
M2/TP7 (+) - TP8 0.46 V
Diode check module M3 M3/TP9 (+) - TP11 0.46 V
M3/TP11 (+) - TP10 0.38 V
M3/TP13 (+) - TP14 0.46 V
M3/TP14 (+) - TP12 0.38 V
NOTE!
The resulting measurement command values change according to the temperature.
Measuring points