EasyManua.ls Logo

Fronius TransSynergic 5000 - Page 53

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
EN
Measuring points Plug/pin Measuring result command
value
Intermediate circuit voltage 1 M1/TP1-TP3 320 V DC
Intermediate circuit voltage 2 M2/TP5-TP7 320 V DC
Diode check module M1 M1/TP1-TP2 (+) 0.46 V
M1/TP1-TP4 (+) 0.46 V
M1/TP3 (+) - TP2 0.46 V
M1/TP3 (+) - TP4 0.46 V
Diode check module M2 M2/TP5-TP6 (+) 0.46 V
M2/TP5-TP8 (+) 0.46 V
M2/TP7 (+) - TP6 0.46 V
M2/TP7 (+) - TP8 0.46 V
Diode check module M3 M3/TP9 (+) - TP11 0.46 V
M3/TP11 (+) - TP10 0.38 V
M3/TP13 (+) - TP14 0.46 V
M3/TP14 (+) - TP12 0.38 V
NOTE!
The resulting measurement command values change according to the temperature.
Measuring points
(continued)

Table of Contents

Other manuals for Fronius TransSynergic 5000

Related product manuals