58
Measuring points
(continued)
Measuring points Plug/pin Measuring result command value
Intermediate circuit voltage 1 TP1-TP3 320 V DC
Intermediate circuit voltage 2 TP5-TP7 320 V DC
Diode check module M1 TP1-TP2 (+) 0.46 V
TP1-TP4 (+) 0.46 V
TP3 (+) - TP2 0.46 V
TP3 (+) - TP4 0.46 V
TP5 - TP6 (+) 0.46 V
TP5 - TP8 (+) 0.46 V
TP7 (+) - TP6 0.46 V
TP7 (+) - TP8 0.46 V
Important! No continuity during diode check of module M1 with reverse polarity.
NOTE!
The resulting measurement command values change according to the temperature.