EasyManua.ls Logo

Fronius TransSynergic 5000 - Page 60

Fronius TransSynergic 5000
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
58
Measuring points
(continued)
Measuring points Plug/pin Measuring result command value
Intermediate circuit voltage 1 TP1-TP3 320 V DC
Intermediate circuit voltage 2 TP5-TP7 320 V DC
Diode check module M1 TP1-TP2 (+) 0.46 V
TP1-TP4 (+) 0.46 V
TP3 (+) - TP2 0.46 V
TP3 (+) - TP4 0.46 V
TP5 - TP6 (+) 0.46 V
TP5 - TP8 (+) 0.46 V
TP7 (+) - TP6 0.46 V
TP7 (+) - TP8 0.46 V
Important! No continuity during diode check of module M1 with reverse polarity.
NOTE!
The resulting measurement command values change according to the temperature.

Table of Contents

Other manuals for Fronius TransSynergic 5000

Related product manuals