62
Measuring points Plug/pin Measuring result command value
Intermediate circuit voltage 1 X1/1 - X1/3 approx. 280 V DC at a nominal voltage of
400 V AC
approx. 320 V DC at a nominal voltage of
230 V AC
Intermediate circuit voltage 2 X1/5 - X1/7 approx. 280 V DC at a nominal voltage of
400 V AC
approx. 320 V DC at a nominal voltage of
230 V AC
+15 V primary X1/8 - X1/7 approx. 15 V DC
+24 V internal X2/4 - X2/8 approx. 24 V DC
+24 V external X2/1 - X2/5 approx. 24 V DC