NOTE!
Switching over from one job to the next without interrupting welding is only possible
with a JobMaster TIG welding torch, robot interface or field bus.
GPr
Gas pre-flow time
Unit s
Setting range 0 - 9,9
Factory setting 0,4
G-L
Gas-Low - gas post-flow time at minimum welding current
(minimum gas post-flow time)
Unit s
Setting range 0 - 25
Factory setting 5
G-H
Gas-High - Increase in the gas post-flow time at maximum welding current
Unit s
Setting range 0 - 40/Aut
Factory setting Aut
For further information on the G-H parameter, see the TIG set-up menu.
tAC
Tacking function: Duration of the pulsed welding current at the start of tacking
Unit s
Setting range OFF / 0.1 - 9.9 / ON
Factory setting OFF
For further information on the tAC parameter, see the TIG set-up menu.
F-P
Frequency-pulsing - Pulse frequency
Unit Hz / kHz
Setting range OFF / 0.20 Hz - 2.00 kHz
Factory setting OFF
For further information on the F-P parameter, see the TIG set-up menu.
dcY
Duty cycle - The ratio of pulse duration to base current duration when a pulse frequency
has been set
Unit %
Setting range 10 - 90
Factory setting 50

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransTig 800 Job and is the answer not in the manual?

Fronius TransTig 800 Job Specifications

General IconGeneral
BrandFronius
ModelTransTig 800 Job
CategoryPortable Generator
LanguageEnglish

Related product manuals