2-5. Slim duct/Slim concealed floor type
Model name ARUL7TLAV2 ARUL9TLAV2 ARUL12TLAV2 ARUL14TLAV2
Power supply 1 phase ~ 208/230 V 60 Hz
Available voltage range 187—253 V
Capacity
Cooling
Btu/h 7,500 9,500 12,000 14,000
kW 2.2 2.8 3.5 4.1
Heating
Btu/h 9,500 10,900 13,500 15,600
kW 2.8 3.2 4.0 4.6
Input power W 44 50 54 92
Static pressure range inWG (Pa) 0 to 0.36 (0 to 90)
Standard static pressure inWG (Pa) 0.10 (25)
Fan
Airflow rate
HIGH
CFM (m
3
/h)
324 (550) 353 (600) 353 (600) 471 (800)
MED—HIGH 283 (480) 300 (510) 312 (530) 401 (680)
MED 259 (440) 271 (460) 289 (490) 353 (600)
MED—LOW 241 (410) 247 (420) 265 (450) 306 (520)
LOW 218 (370) 218 (370) 241 (410) 259 (440)
QUIET 188 (320) 188 (320) 200 (340) 200 (340)
Type × Q'ty Sirocco × 2
Motor output W 80 81
Sound pressure level*
HIGH
dB (A)
28 29 30 34
MED—HIGH 26 27 28 32
MED 25 25 27 30
MED—LOW 24 24 26 28
LOW 22 22 24 25
QUIET 21 21 22 22
Heat exchanger type
Length in (mm) 19-11/16 (500)
Fin pitch FPI 19
Rows × Stages 2 × 14 3 × 14
Face area
ft
2
(m
2
)
1.6 (0.14)
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit (Aluminum)
Surface treatment Hydrophilic coating
Air filter
Type Fungicide type
Net material PP honeycomb
Enclosure
Material Galvanized sheet iron
Color
Dimensions
(H × W × D)
Net
in (mm)
7-13/16 × 27-9/16 × 24-7/16 (198 × 700 × 620)
Gross 10-7/8 × 38-1/8 × 30-3/8 (276 × 968 × 772)
Weight
Net
lb (kg)
37 (17) 40 (18)
Gross 46 (21) 51 (23)
Connection pipe diameter
Liquid (Flare)
in (mm)
Ø 1/4 (6.35)
Gas (Flare) Ø 3/8 (9.52) Ø 1/2 (12.70)
Drain hose I.D.: Ø 3/4 (19.05); O.D.: Ø 1-1/16 (26.6)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-5. Slim duct/Slim concealed floor type - (04-11) - 2. Specifications