EasyManua.ls Logo

Fujitsu AIRSTAGE J-IIIL - Compact Floor Type

Fujitsu AIRSTAGE J-IIIL
904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-8. Compact floor type
Model name AGUA4TLAV1 AGUA7TLAV1 AGUA9TLAV1
Power supply 1 phase ~ 208/230 V 60 Hz
Available voltage range 187—253 V
Capacity
Cooling
Btu/h 4,000 7,500 9,500
kW 1.2 2.2 2.8
Heating
Btu/h 4,400 9,500 10,900
kW 1.3 2.8 3.2
Input power W
12/14*
1
16 17
Fan
Airflow rate
HIGH
CFM (m
3
/h)
224/253*
1
(380/430
*
1
)
277 (470) 294 (500)
MED—HIGH 206 (350) 247 (420) 265 (450)
MED 188 (320) 230 (390) 235 (400)
MED—LOW 182 (310) 212 (360) 212 (360)
LOW 165 (280) 194 (330) 194 (330)
QUIET 124 (210) 159 (270) 159 (270)
Type × Q'ty Crossflow × 2
Motor output W 16 × 2
Sound pressure level*
2
HIGH
dB (A)
35/36*
1
37 38
MED—HIGH 33 35 36
MED 31 33 34
MED—LOW 30 31 31
LOW 28 29 29
QUIET 22 22 22
Heat exchanger type
Length in (mm) 21-5/8 (550)
Fin pitch FPI 21
Rows × Stages 2 × 18
Face area
ft
2
(m
2
)
2.3 (0.21)
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit (Aluminum)
Surface treatment Hydrophilic coating
Air filter
Type Anti-mold
Net material PP plain weave
Enclosure
Material Plastic
Color
White
Approximate color of Munsell 5Y 9/0.5NN
Dimensions
(H × W × D)
Net
in (mm)
23-5/8 × 29-1/8 × 7-7/8 (600 × 740 × 200)
Gross 27-9/16 × 32-5/16 × 12-3/16 (700 × 820 × 310)
Weight
Net
lb (kg)
33 (15)
Gross 41 (18.5) 42 (19)
Connection pipe diameter
Liquid (Flare)
in (mm)
Ø 1/4 (6.35)
Gas (Flare) Ø 3/8 (9.52)
Drain hose I.D.: Ø 9/16 (13.8); O.D.: Ø 5/8 to 11/16 (15.8 to 16.7)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*1: This value is “Cooling operation/Heating operation”.
*2: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
2-8. Compact floor type - (04-16) - 2. Specifications
INDOOR
UNITS
INDOOR
UNITS

Table of Contents

Related product manuals