Model name AGUA12TLAV1 AGUA14TLAV1
Power supply 1 phase ~ 208/230 V 60 Hz
Available voltage range 187—253 V
Capacity
Cooling
Btu/h 12,000 14,000
kW 3.5 4.1
Heating
Btu/h 13,500 15,600
kW 4.0 4.6
Input power W 22 29
Fan
Airflow rate
HIGH
CFM (m
3
/h)
347 (590) 394 (670)
MED—HIGH 306 (520) 347 (590)
MED 277 (470) 306 (520)
MED—LOW 247 (420) 265 (450)
LOW 230 (390) 230 (390)
QUIET 200 (340) 200 (340)
Type × Q'ty Crossflow × 2
Motor output W 16 × 2
Sound pressure level*
HIGH
dB (A)
42 46
MED—HIGH 39 42
MED 37 39
MED—LOW 35 36
LOW 33 33
QUIET 30 30
Heat exchanger type
Length in (mm) 21-5/8 (550)
Fin pitch FPI 21
Rows × Stages 2 × 18
Face area
ft
2
(m
2
)
2.3 (0.21)
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit (Aluminum)
Surface treatment Hydrophilic coating
Air filter
Type Anti-mold
Net material PP plain weave
Enclosure
Material Plastic
Color
White
Approximate color of Munsell 5Y 9/0.5NN
Dimensions
(H × W × D)
Net
in (mm)
23-5/8 × 29-1/8 × 7-7/8 (600 × 740 × 200)
Gross 27-9/16 × 32-5/16 × 12-3/16 (700 × 820 × 310)
Weight
Net
lb (kg)
33 (15)
Gross 42 (19)
Connection pipe diameter
Liquid (Flare)
in (mm)
Ø 1/4 (6.35)
Gas (Flare) Ø 1/2 (12.70)
Drain hose I.D.: Ø 9/16 (13.8); O.D.: Ø 5/8 to 11/16 (15.8 to 16.7)
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80 °FDB/67 °FWB (26.7 °CDB/19.4 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
Heating: Indoor temperature of 70 °FDB/60 °FWB (21.1 °CDB/15.6 °CWB), and outdoor temperature of 47 °FDB/43 °FWB (8.3 °CDB/6.1 °CWB).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.