7. Optional parts installation
7-1. Drain pump unit for duct type
RELATED LINKS
"Applicable parts
" on page 10-18
¢
S
pecifications
Model name UTZ-PU1NBA
Height of drain up in (mm) Maximum 39-3/8 (1,000)
Power source 220—240 V, 50/60 Hz
Power input (230 V, 50/60 Hz) W 12/10.8
Current (230 V, 50/60 Hz) mA 114/92
Dimensions (H × W × D) in (mm) 6-15/16 × 7 × 6-1/16 (176 × 178 × 154)
Weight lb (kg) 6 (2.5)
Connection pipe diameter in (mm) I.D.: 3/4 (19.05), O.D.: 1-1/16 (27)
Direction of pipe connection*
1
360°
Angle of pipe connection *
2
0° to 90° (Horizontal to vertical)
Control method Control board of indoor unit
Safety device Float switch, Thermal fuse
*1: Direction of pipe connection *2: Angle of pipe connection