Control
Primary
heater
Auxiliary
heater
Installation
configuration
Function setting
Wired remote
controller
Outdoor unit
Sensor activation
Presence of heater
selection control
using outdoor unit
sensor
UTY-RNRUZ
UTY-RSRY
UTY-RHRY
UTY-RNKU
Function no: 35
Auxiliary heater
control 1
VRF heat
pump
External
device
In-line
Individual
Auxiliary heater
control 2
VRF heat
pump
External
device
In-line
Individual
Heat pump
prohibition control
External
device
None
In-line
Individual
On (Enabled)*
1
Auxiliary heater
control by outdoor
temperature 1
VRF heat
pump
External
device*
2
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
Auxiliary heater
control by outdoor
temperature 2
VRF heat
pump
External
device
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
Auxiliary heater
control by outdoor
temperature 3
VRF heat
pump
External
device*
2
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
Auxiliary heat
pump control
External
device
VRF heat
pump
In-line
Individual
On (Enabled)*
1
Auxiliary heat
pump control by
outdoor
temperature 1
External
device
VRF heat
pump*
3
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
Auxiliary heat
pump control by
outdoor
temperature 2
External
device
VRF heat
pump*
2
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
Auxiliary heat
pump control by
outdoor
temperature 3
External
device
VRF heat
pump*
2
*
3
In-line
35-01
(Enabled)
Individual
On (Enabled)*
1
NOTES:
Corresponding indoor units: Except wall mounted type
After turning off the heater, 3 minutes of standby time is required by next power-on of the
heater.
For items marked “—” in the table, any of validate or invalidate of the setting are acceptable.
For items marked in orange in the table, setting change from the factory setting is required.
*1: Indoor unit fan setting will be on for safety reason without sensor activation of wired remote
controller.
*2: Heating operation is not performed when the outdoor temperature exceeds the boundary
specified in function setting number 37.
*3: Heating operation is not performed when the outdoor temperature is lower than the bound-
ary specified in function setting number 36.
3-3. External output - (08-37) - 3. Indoor unit
EXTERNAL INPUT
AND OUTPUT
EXTERNAL INPUT
AND OUTPUT