Model Menu (Airplane/Glider Functions)
ŏ5HWXUQWR0RGHO0HQX
*\UR
>&RUUHVSRQGLQJPRGHOW\SH@$LUSODQHJOLGHUJHQHUDO
This function is used when a gyro is used to
stabilize the fuselage attitude. The sensitivity and
operation mode (Normal mode/GYmode) can be
switched with a switch.
ŏ7KUHHUDWHV5DWH5DWH5DWHFDQEHVZLWFKHG
ŏ8SWRD[HV*\UR*\UR*\URFDQEH
simultaneously controlled.
ŏ7RXFKWKH>*\UR@EXWWRQLQWKH0RGHO0HQX
WRFDOOWKHVHWXSVFUHHQVKRZQEHORZ
*Initial setting does not assign a sensitivity channel. Use the
Function menu of the Linkage Menu to assign the sensitivity
channel (Gyro/Gyro2/Gyro3) used to a vacant channel
beforehand.
Set [ACT] and [Trim] other than Function to [NULL].
ŏ7KHRSHUDWLRQPRGH$9&6125DQGVHQVLWLYLW\RI
WKHD[HV*\UR*\UR*\URFDQEHVHW
ŏ*URXSVLQJOHPRGHVZLWFKLQJ*U
6QJO
(For more information, see the description
DWWKHEDFNRIWKLVPDQXDO
ŏ7KUHHUDWHV5DWH5DWH5DWHFDQEHXVHG
ŏ7RXFKWKH$&7EXWWRQRIWKHUDWHWREHXVHGDQGVHWWKHIXQFWLRQWR$&7>21@RU>2))@
ŏ:KHQD)XWDEDJ\URLVXVHGZKHQ>*<@W\SHLVVHOHFWHGWKHVHQVLWLYLW\VHWYDOXHLV
GLUHFWO\UHDGLQERWKWKH$9&6DQG125PRGHV
ŏ:KHQVHWWLQJDVZLWFKWRXFKWKHVZLWFKEXWWRQWRFDOOWKH6ZLWFK!VFUHHQDQGWKHQ
VHOHFWWKHVZLWFKDQGVHWLWV21GLUHFWLRQ
([DPSOH6HWWLQJWKUHHD[LVXVLQJD*<$DQG*<$
ŏ:LQJW\SH$LOHURQVHUYRVPRXQWHGIXVHODJHVHOHFWHG
ŏ6HW
5CH GYRO
*<$$,/
7CH GYRO2
*<$(/(
8CH GYRO3
*<$58'
ControlandTrim NULL

DWWKH)XQFWLRQPHQXRIWKH/LQNDJHPHQX
ŏ*<52VHWWLQJRIWKH0RGHOPHQX
*Set so that Rate 1 is turned on at the back position of switch
E and Rate 3 is turned ON at the front position. Since switch
E is turned OFF at the center, Rate 2 remains [INH].
Rudderservo
Elevatorservo
GYA430
GYA431
GYA431
Aileronservo
S.BUS2port
R7008SB
GAIN0%
AVCS
NORMAL
WhenAVCSisusedwe
recommendthatthe
sensitivityCHbesetto
the3-position.
Rate ACT Type Switch GYRO GYRO GYRO
1 OFF/ON GY SE AVCS:60% AVCS:60% AVCS:60%
2INH
3 ON/OFF GY SE NORM:60% NORM:60% NORM:60%
$,53/$1(*/,'(5