MDS 05-4846A01, Rev. D SD Series Technical Manual 73
010 Major Flash write failure.
011 Major Checksum fault.
012 Major Receiver time-out. No data received within the specified
receiver time-out time.
013 Major Transmitter time-out.
014 Major #14 Reserved.
015 Major VSWR fault. Possible antenna/feedline problem.
068 Major Excessive Ethernet traffic on interface.
016 Minor Unit address not programmed.
017 Minor Data parity error. This usually indicates a parity setting
mismatch between the radio and the RTU.
018 Minor Data framing error. May indicate a baud rate mismatch
between the radio and connected equipment.
019 Minor #19 Reserved.
020 Minor Configuration error.
021 Minor #21 Reserved.
022 Minor #22 Reserved.
023 Minor #23 Reserved.
024 Minor #24 Reserved.
025 Minor 6v regulator output not in valid range. If the voltage is too far
out of tolerance, operation may fail.
026 Minor DC input voltage approaching limit. If the voltage is too far out
of tolerance, operation may fail.
027 Minor #27 Reserved.
028 Minor #28 Reserved.
029 Minor RF Output Power not in valid range.
030 Minor #30 Reserved.
031 Minor Internal temperature approaching limit.
037 Minor Unexpectedly executing APP 1.
038 Minor Unexpectedly executing APP 2.
039 Minor Boot error; active image unknown.
042 Minor Reprogramming failure.
064 Minor A socket operation failed.
070 Minor AP not available.
041 Status Forced restart of Ethernet interface.
043 Status Reprogramming in progress.