Advanced Operation
Commands
#set_feedback
Enable or disable unsolicited command feedback for RS-232, TCP, and UDP protocols.
The default value is On.
Syntax
#set_feedback param1
Parameters
param1 Integer [0 ... 1]
param1 Description
0
Off
1
On
Example
#set_feedback 1
FEEDBACK IS ON
Notes
Feedback shall be sent whenever a status is changed, whether it is changed by
RS-232, Web GUI, IR, Contact closure, or Front Panel buttons.
Feedback shall be the same as #get_feedback Command.
Feedback can be turned off via the #set_feedback Command.