Page 16 VRC2000 Installation and Operations Manual
Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • Worldwide Web @ http://www.gentner.com
The VRC2000 will respond:
• VOICE ON.
The VRC2000 will accept very long strings of numbers when the voice
function is disabled, although you can only enter one programming sequence
at a time. If an invalid code number is entered with the voice function off,
the VRC2000 will respond with an ERROR message.
VOICE FUNCTION NOTE:
The voice function will automatically be turned back on after a valid
programming sequence is entered. You will hear an ERROR message after the
voice function is turned off if you enter an invalid programming sequence; begin
the programming sequence for the parameter again if an ERROR message is
received.
Toggling Between User and Setup Modes
Toggling between the user and setup modes can be done at any time. When
in local setup mode, toggle to the local user mode by entering
☎ “9 2 0”
The VRC2000 will respond:
• USER ENABLED.
Toggle back to local setup mode by entering the same “9 2 0” sequence.
When in the remote user mode, toggle to remote setup mode by entering
☎ “9 1 0”
The VRC2000 will say
• SETUP ENABLED. PLEASE ENTER SYSTEM ACCESS CODE.
Now enter the correct seven-digit system access code in order to proceed with
any set-up function.
Toggle back to remote user mode by entering the same “9 1 0” sequence.
SETUP MODE NOTE:
The setup mode cannot be entered from the operator security level. Attempting
to do so will result in an ERROR message.
Changing the System Identifier
The system identifier is the greeting the VRC2000 gives when a user signs
on to the system; it can be customized, as long as it is composed of exactly
20 words.
The default system identifier states
• HELLO. THIS IS THE VRC2000 WITH VOICE, MODEM OR RADIO ACCESS.
PLEASE ENTER ACCESS CODE.
VRC2000 Setup