VRC2000 Installation and Operations Manual Page 65
Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) Worldwide Web @ http://www.gentner.com
ensures that alarm logs are always reported before being cleared.
Auto-Logging Programming Exercise
The following autologging programming exercise will illustrate more fully
how to program auto-logging. The exercise entails setting the auto-logging
function to begin generation logs at 6:05 a.m. every day, and stop generating
logs at 7:45 p.m. every evening; the logs will be generated every 90 minutes.
AUTO-LOGGING PROGRAMMING NOTE:
You must be in the set-up mode in order to change the set up for an auto-logging
function.
AUTO-LOGGING TIME NOTE:
The interval for auto-logging cannot cross midnight. In other words, logging
cannot run from 7:45 p.m.–6:05 a.m. (for example).
First, enter
“0 2 0 #”
The VRC2000 will respond
• TIME-OF-DAY HOURS FOR LOGGING START TIME ARE ... {TWELVE}
You enter
“0 6”
The VRC2000 will respond with a double [BEEP].
Auto-logging will now start at the sixth hour of the day.
TIME NOTE:
Enter two digits for all time entries.
The VRC2000 will say
• TIME-OF-DAY MINUTES FOR LOGGING START TIME ARE ... {ZERO}
You enter
“0 5”
The VRC2000 will respond with a double [BEEP].
Auto-logging will now start at the fifth minute of the selected hour.
The VRC2000 will say
• TIME-OF-DAY FOR LOGGING START IS ... {AM}
You enter
“*”