GM Energy V2H Bundle Installation Manual 34
Conductors without a torque value are landed at lever attachments and therefore require no torque value. Ensure that
you wire all the following connections (Figure 21 and Table 5):
Inverter Wiring
Type
Qty.
AWG Size
Strip Length /
Torque IF
APPLICABLE
Color
Label
1
DC
Charger
2
8
0.75
1 Red
1 Black
@Inverter:
EV+ Red
EV− Black
@Charger:
EV+ Red
EV− Black
2
Future
Feature
3
Future
Feature
4
Hub AC
3
1
6
10
0.7
0.5” (16 in-lb)
1 Black
1 Red
1 White
1 Green
@Inverter:
L1 Black
N White
L2 Red
G Green
@Hub: L1 L2 breaker in the
backup pan, N bar and
Ground bar
5
Comm
2
twisted
pair
Recommend:
18
(Acceptable:
1423)
0.4
1 Red
1 Black
1 Black/White
twisted pair
@Inverter
EVSE*:
DS Black
EPO Red
H Black
L White
@Charger*:
CAN L White
CAN H Black
DS Black
EPO Red
RSD
2
12 to 18
0.5”
Any
@Inverter :
RSD 1 / RSD 2
Color and termination per
RSD switch.
If system does NOT have a
Rapid Shutdown Device
installed, RSD 1 and RSD 2
must be jumpered
6
9.6 VDC
2
10
0.6
1 Red
1 Black
@Inverter
EVSE:
+12V Red
GND Black
@Charger:
+12V Red
GND Black
9.6 VDC
2
10
0.6
1 Red
1 Black
@Inverter
MID:
+12V Red
GND Black
@Hub:
+12V Red
GND Black
7
Comm
4
14
0.6
(factory stripped)
1 Black
1 Red
1 Green
1 White
@Inverter
DSB:
+12V Red
GND Black
A Green
B White
@DSB:
Factory wire connection.
Add cable gland or raceway
fitting.