EasyManua.ls Logo

GM V2H Bundle - GM Energy Dark Start Battery

Default Icon
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GM Energy V2H Bundle Installation Manual 9
Equipment Requirements
The following sections summarize temperature, clearance, and distance between equipment requirements. See also the
summaries in the respective Quick Installation Guide (QIG, included in the box of each piece of equipment).
Temperature
Component
Max. Low
Temp.
(shipping/
storage)
Operating
Min. Temp.
Operating
Max. Temp.
Max. High Temp.
(shipping/storage)
GM Energy
PowerShift
Charger
−40°F (−40°C)
40°F (40°C)
122°F (50°C)
176°F (80°C)
Hub
−40°F (−40°C)
−4°F (−20°C)
122°F (50°C)
185°F (85°C)
Inverter
−40°F (−40°C)
−22°F (−30°C)
149°F (65°C); with
derating above
113°F (45°C)
185°F (85°C)
Dark Start:
Charge
−40°F (−40°C)
32°F (0°C)
113°F (45°C)
185°F (85°C)
Dark Start:
Discharge
−4°F (−20°C)
122°F (50°C)
Sun shading is recommended for installation locations exposed to direct sunlight where ambient temperatures exceed 104°F
(40°C).