58
COOLING PERFORMANCE DATA
VSH130361A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: VSH130361A* / AR*F364216B* Design Subcooling 9 ±3 °F @ the liquid service valve, AHRI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 6
6
71 59 63 67 71 59 6
6
71 59 6
67 71 59 63 6
71 59 6
67 71
MBh 33.8 35.0 38.4 - 33.0 34.2 37.5 - 32.2 33.4 36.6 - 31.4 32.6 35.7 - 29.9 31.0 33.9 - 27.7 28.7 31.4 -
S/T 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.80 0.67 0.47 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.73 0.50 -
DELTA T 17 14 11 - 17 14 11 - 17 14 11 - 17 15 11 - 17 14 11 - 16 13 10 -
1425 KW 2.47 2.52 2.60 - 2.65 2.70 2.79 - 2.81 2.86 2.95 - 2.95 3.01 3.10 - 3.06 3.13 3.23 - 3.16 3.23 3.33 -
AMPS 9.2 9.4 9.7 - 9.9 10.1 10.5 - 10.7 11.0 11.3 - 11.5 11.7 12.1 - 12.2 12.5 12.9 - 12.9 13.2 13.6 -
HI PR 143 154 163 - 161 173 183 - 183 197 208 - 208 224 236 - 234 252 266 - 259 278 294 -
LO PR 65 69 76 - 69 73 80 - 72 76 83 - 75 80 87 - 79 84 91 - 81 87 95 -
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
DELTA T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
70 1275 KW 2.46 2.51 2.58 - 2.64 2.69 2.77 - 2.79 2.85 2.94 - 2.93 2.99 3.08 - 3.05 3.11 3.21 - 3.15 3.21 3.32 -
AMPS 9.1 9.3 9.6 - 9.8 10.1 10.4 - 10.7 10.9 11.3 - 11.4 11.7 12.0 - 12.1 12.4 12.8 - 12.8 13.1 13.6 -
HI PR 142 153 162 - 159 172 181 - 181 195 206 - 207 222 235 - 232 250 264 - 257 276 292 -
LO PR 65 69 75 - 68 73 79 - 71 76 82 - 75 79 87 - 78 83 91 - 81 86 94 -
MBh 31.6 32.8 35.9 - 30.9 32.0 35.1 - 30.2 31.3 34.3 - 29.4 30.5 33.4 - 28.0 29.0 31.7 - 25.9 26.8 29.4 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
DELTA T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1125 KW 2.42 2.47 2.54 - 2.60 2.65 2.73 - 2.75 2.81 2.89 - 2.88 2.94 3.03 - 3.00 3.06 3.16 - 3.10 3.16 3.26 -
AMPS 9.0 9.2 9.5 - 9.7 9.9 10.2 - 10.5 10.7 11.1 - 11.2 11.4 11.8 - 11.9 12.2 12.6 - 12.6 12.9 13.3 -
HI PR 139 150 158 - 156 168 178 - 178 191 202 - 202 218 230 - 228 245 259 - 252 271 286 -
LO PR 63 67 74 - 67 71 78 - 70 74 81 - 73 78 85 - 77 82 89 - 79 84 92 -
MBh 34.37 35.39 38.30 41.11 33.57 34.56 37.41 40.15 32.77 33.74 36.52 39.20 31.97 32.92 35.63 38.24 30.37 31.27 33.85 36.33 28.14 28.97 31.36 33.65
S/T 0.860.770.580.370.890.800.600.390.910.820.620.400.94 0.84 0.64 0.410.980.880.660.430.990.880.670.43
DELTA T19181410191815101918151019 18 15 1019181410181714 9
1425 KW 2.49 2.54 2.62 2.69 2.67 2.72 2.81 2.89 2.83 2.89 2.98 3.07 2.97 3.03 3.13 3.23 3.09 3.15 3.25 3.36 3.19 3.26 3.36 3.47
AMPS 9.3 9.5 9.8 10.1 10.0 10.2 10.5 10.9 10.8 11.1 11.4 11.9 11.6 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.0 13.3 13.8 14.3
HI PR 145 156 164 171 162 175 184 192 185 199 210 219 210 226 239 249 236 254 269 280 261 281 297 310
LO PR 66 70 76 81 70 74 81 86 72 77 84 89 76 81 88 94 80 85 92 98 82 88 96 102
MBh 33.934.937.740.533.134.136.939.632.333.236.038.631.5
32.4
35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.820.740.560.360.850.760.580.370.880.780.590.380.90
0.81
0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
DELTA T20191510201915112019151121
19
15 11 20 19 15 11 19 17 14 10
75 1275 KW 2.48 2.53 2.60 2.68 2.66 2.71 2.79 2.88 2.81 2.87 2.96 3.05 2.95
3.01
3.11 3.21 3.07 3.14 3.23 3.34 3.17 3.24 3.34 3.45
AMPS 9.2 9.4 9.7 10.1 9.9 10.2 10.5 10.9 10.8 11.0 11.4 11.8 11.5
11.8
12.1 12.6 12.2 12.5 12.9 13.4 12.9 13.2 13.7 14.2
HI PR 144 155 163 170 161 173 183 191 183 197 208 217 209
225
237 247 235 253 267 278 259 279 295 307
LO PR 65 70 76 81 69 73 80 85 72 76 83 89 75
80
88 93 79 84 92 98 82 87 95 101
MBh 32.2 33.1 35.9 38.5 31.4 32.4 35.0 37.6 30.7 31.6 34.2 36.7 29.9 30.81 33.3 35.8 28.4 29.3 31.7 34.0 26.3 27.1 29.3 31.5
S/T 0.790.710.530.340.820.730.550.360.840.750.570.370.87 0.77 0.59 0.380.900.800.610.390.910.810.610.39
DELTA T21191611211916112119161121 20 16 112119161120181510
1125 KW 2.44 2.49 2.56 2.64 2.62 2.67 2.75 2.83 2.77 2.83 2.91 3.00 2.91 2.97 3.06 3.16 3.02 3.09 3.18 3.28 3.12 3.19 3.29 3.39
AMPS 9.0 9.2 9.5 9.9 9.7 10.0 10.3 10.7 10.6 10.8 11.2 11.6 11.3 11.5 11.9 12.4 12.0 12.3 12.7 13.2 12.7 13.0 13.4 13.9
HI PR 141 151 160 167 158 170 179 187 180 193 204 213 205 220 232 242 230 248 261 273 254 274 289 301
LO PR 64 68 74 79 68 72 79 84 70 75 82 87 74 79 86 91 77 82 90 96 80 85 93 99
Shaded area is ACCA (TVA) conditions IDB: Enteri ng Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.