14
COOLING PERFORMANCE DATA
GSH130191A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH130191A* / AWUF18XX1A* Design Subcooling 9 ±3 °F @ the liquid service valve, AHRI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
MBh 17.6 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1 - 16.4 17.0 18.6 - 15.6 16.2 17.7 - 14.4 15.0 16.4 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.86 0.71 0.50 - 0.86 0.72 0.50 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
675 KW 1.25 1.27 1.31 - 1.33 1.36 1.40 - 1.41 1.44 1.48 - 1.47 1.50 1.55 - 1.53 1.56 1.61 - 1.58 1.61 1.66 -
AMPS 4.0 4.1 4.2 - 4.3 4.4 4.5 - 4.6 4.7 4.9 - 4.9 5.0 5.2 - 5.2 5.3 5.4 - 5.4 5.6 5.7 -
HI PR 136 146 155 - 153 164 173 - 174 187 197 - 198 213 225 - 222 239 253 - 246 264 279 -
LO PR 61 65 71 - 65 69 75 - 67 71 78 - 70 75 82 - 74 79 86 - 76 81 89 -
MBh 17.1 17.7 19.4 - 16.7 17.3 19.0 - 16.3 16.9 18.5 - 15.9 16.5 18.1 - 15.1 15.7 17.2 - 14.0 14.5 15.9 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
Delta T 19 16 12 - 19 16 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
70 600 KW 1.24 1.26 1.30 - 1.32 1.35 1.39 - 1.40 1.43 1.47 - 1.46 1.49 1.54 - 1.52 1.55 1.60 - 1.57 1.60 1.65 -
AMPS 4.0 4.1 4.2 - 4.3 4.4 4.5 - 4.6 4.7 4.8 - 4.9 5.0 5.1 - 5.1 5.2 5.4 - 5.4 5.5 5.7 -
HI PR 135 145 153 - 151 163 172 - 172 185 195 - 196 211 222 - 220 237 250 - 243 262 277 -
LO PR 61 64 70 - 64 68 74 - 66 71 77 - 70 74 81 - 73 78 85 - 76 80 88 -
MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.79 0.66 0.46 -
Delta T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
525 KW 1.22 1.24 1.27 - 1.30 1.32 1.36 - 1.37 1.39 1.43 - 1.43 1.46 1.50 - 1.48 1.51 1.56 - 1.53 1.56 1.61 -
AMPS 3.9 4.0 4.1 - 4.2 4.3 4.4 - 4.5 4.6 4.7 - 4.7 4.8 5.0 - 5.0 5.1 5.3 - 5.3 5.4 5.5 -
HI PR 131 141 148 - 147 158 167 - 167 179 189 - 190 204 216 - 214 230 243 - 236 254 268 -
LO PR 59 62 68 - 62 66 72 - 64 69 75 - 68 72 79 - 71 75 82 - 73 78 85 -
MBh 17.94 18.47 19.99 21.45 17.52 18.04 19.53 20.96 17.10 17.61 19.06 20.46 16.69 17.18 18.60 19.96 15.85 16.32 17.67 18.96 14.68 15.12 16.36 17.56
S/T 0.85 0.76 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.61 0.40 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43
Delta T21 191611 21 1916 11 211916 11 2120 16 1121 19161120181510
675 KW 1.26 1.28 1.32 1.36 1.34 1.37 1.41 1.45 1.42 1.45 1.49 1.53 1.49 1.52 1.56 1.61 1.54 1.57 1.62 1.67 1.59 1.62 1.67 1.72
AMPS 4.1 4.1 4.3 4.4 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 4.9 5.0 5.2 5.4 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.0
HI PR 137 148 156 163 154 166 175 183 175 189 199 208 200 215 227 237 225 242 255 266 248 267 282 294
LO PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95
MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2
16.7
18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1
S/T 0.82 0.73 0.55 0.35 0.84 0.76 0.57 0.37 0.87 0.77 0.59 0.38 0.89
0.80
0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
Delta T22201611222017112220171122
20
17 12 22 20 17 11 20 19 15 11
75 600 KW 1.25 1.27 1.31 1.35 1.33 1.36 1.40 1.44 1.41 1.44 1.48 1.52 1.47
1.50
1.55 1.60 1.53 1.56 1.61 1.66 1.58 1.61 1.66 1.71
AMPS 4.0 4.1 4.2 4.4 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.0 4.9
5.0
5.2 5.3 5.25.35.45.65.55.65.75.9
HI PR 136 146 155 161 153 164 173 181 174 187 197 206 198
213
225 234 222 239 253 264 246 265 279 291
LO PR 61 65 71 76 65 69 75 80 67 71 78 83 71
75
82 87 74 79 86 91 76 81 89 95
MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.40 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7
S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.89 0.80 0.61 0.39 0.90 0.81 0.61 0.39
Delta T22 201712 22 2117 12 222117 12 2321 17 1222 20171221191611
525 KW 1.22 1.25 1.28 1.32 1.31 1.33 1.37 1.41 1.38 1.40 1.45 1.49 1.44 1.47 1.51 1.56 1.50 1.53 1.57 1.62 1.54 1.57 1.62 1.67
AMPS 3.9 4.0 4.1 4.3 4.2 4.3 4.4 4.5 4.5 4.6 4.7 4.9 4.8 4.9 5.0 5.2 5.0 5.2 5.3 5.5 5.3 5.4 5.6 5.8
HI PR 132 142 150 156 148 159 168 176 168 181 191 200 192 206 218 227 216 232 245 256 238 257 271 283
LO PR 59 63 69 73 63 67 73 77 65 69 76 81 68 73 79 85 72 76 83 89 74 79 86 92
Shaded area i s ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total s
stem powe
AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.