WIRING DIAGRAMS
24
WARNING
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
ASH130[18-60]1A*
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
COMP
IO
T1
C
M
A
I
N
R
A
U
X
5
S
SR
SA
2
1
RCCF
SC
T2
C
L1
L2
CH
C
F
LPS
OR
YL
BL
RD
O
Y
C
R
T1
L1
T2
L2
RD
SA
(IF USED)
NOTE 2
LVJB
SC
RD BL
L2
T2
L1
T1
C
BK
BK
BK
RD
RD
BK
BL
YL
YL
BL
RD
RCCF
F
YL
YL
YL
BR
RD
PU
YL
RD
SR
5
2
1
BK
YL
BL
YL
C
R
S
RD
BK
AUX
MAIN
COMP
BK
DFT
YL
YL
LPS
DF1
DF2
HVDR
CH
W2
LVDR
O
R
O
O
Y
C
RVC
W2
R
C
DFT
C
Y
DC
R
DFT
RVC
BK
RD
RD
BK
CH
BK
BK BK
WH W2
DC
OR
C Y
O O
BL
YL BK
RD
R R
RD
LVDR
W2
WH
DFT
RD
H
V
D
R
DF2
DF1
BK
BK
SCR
BK
RD YL
Y
CR
BL
RD
YL
RD
BK
YL
2
13
BK
BK
IO
CM
AUX
MAIN
BK
(HIGH)
BR
PU
RD
(LOW)
RD
YL
BL
CADM
C
A
D
M
M
A
I
N
A
U
X
IO
CM
(
L
O
W
)
3
2
(HIGH)
1
C
R
Y
C
A
D
M
CMR
4
5
CMR
2
4
1
3
CMR
2
5
RD
BK
BK
BL
BL OR
OR
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
3) CRANKCASE HEATER MAY BE
FACTORY OR FIELD INSTALLED.
4) LAT POSITION SHOWN FOR HIGH
AMBIENT TEMPERATURE
.
: GOODMAN PRINT SHOP 08/05 0140R00021P
USE N.E.C. CLASS 2 WIRE
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
VENDOR
COMPONENT CODE
C --------------- CONTACTOR
CADM --------
COMFORT ALERT DIAGNOSTIC MODULE
CH ------------- CRANKCASE HEATER
CM ------------ OUTDOOR FAN MOTOR
CMR ---------- CONDENSER MOTOR RELAY
COMP -------- COMPRESSOR
DC ------------- DEFROST CONTROL
DFT ----------- DEFROST THERMOSTAT
HVDR -------- HIGH VOLTAGE DEFROST RELAY
IO -------------- INTERNAL OVERLOAD
LAT ------------ LOW AMBIENT THERMOSTAT
LPS
------------ LOW PRESSURE SWITCH
LVDR --------- LOW VOLTAGE DEFROST RELAY
LVJB
---------- LOW VOLTAGE
JUNCTION BOX
RCCF
--------- RUN CAPACITOR FOR COMPRESSOR & FAN
RVC ----------- REVERSING VALVE COIL
SA ------------- START ASSIST
SC
------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
S
R
------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
INDOOR POWER
SUPPLY
CONTROL BOX
OUTDOOR POWER SUPPLY
SEE RATING PLATE
NOTE 1
(IF USED) NOTE 3
CADM
C
HERM
LAT
NOTE 4
(IF USED)
NOTE 3
ALTERNATE DOUBLE
POLE CONTACTOR ONLY
(IF USED)
NOTE 3
LAT
NOTE 4
(IF USED)
CADM