64
COOLING PERFORMANCE DATA
VSH130601A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: VSH130601A* / AR*F486016B* Design Subcooling 9 ±3 °F @ the liquid service valve, AHRI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 6
71 59 63 67 71 59 6
6
71 59 6
67 71 59 63 6
71 59 6
67 71
MBh 54.4 56.4 61.8 - 53.1 55.1 60.3 - 51.9 53.7 58.9 - 50.6 52.4 57.5 - 48.1 49.8 54.6 - 44.5 46.1 50.6 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
DELTA T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
2025 KW 3.84 3.92 4.03 - 4.12 4.20 4.32 - 4.36 4.45 4.58 - 4.57 4.67 4.81 - 4.75 4.85 5.00 - 4.91 5.01 5.17 -
AMPS 13.8 14.1 14.6 - 14.9 15.2 15.7 - 16.2 16.6 17.1 - 17.3 17.7 18.3 - 18.4 18.8 19.5 - 19.5 20.0 20.6 -
HI PR 140 151 159 - 157 169 179 - 179 193 204 - 204 220 232 - 229 247 261 - 254 273 288 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 82 - 73 78 85 -
MBh 52.8 54.7 60.0 - 51.6 53.5 58.6 - 50.3 52.2 57.2 - 49.1 50.9 55.8 - 46.7 48.4 53.0 - 43.2 44.8 49.1 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -
DELTA T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 1800 KW 3.81 3.89 4.00 - 4.09 4.17 4.29 - 4.32 4.41 4.55 - 4.54 4.63 4.77 - 4.72 4.81 4.96 - 4.87 4.97 5.13 -
AMPS 13.7 14.0 14.4 - 14.8 15.1 15.6 - 16.0 16.4 17.0 - 17.1 17.5 18.1 - 18.2 18.7 19.3 - 19.3 19.8 20.5 -
HI PR 139 150 158 - 156 168 177 - 177 191 202 - 202 217 230 - 227 245 258 - 251 270 285 -
LO PR 58 62 68 - 61 65 71 - 64 68 74 - 67 71 78 - 70 75 82 - 73 77 84 -
MBh 48.7 50.5 55.3 - 47.6 49.3 54.1 - 46.5 48.2 52.8 - 45.3 47.0 51.5 - 43.1 44.6 48.9 - 39.9 41.4 45.3 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -
DELTA T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 13 - 18 15 12 -
1575 KW 3.73 3.80 3.91 - 3.99 4.07 4.19 - 4.23 4.31 4.44 - 4.43 4.52 4.66 - 4.60 4.70 4.85 - 4.75 4.85 5.01 -
AMPS 13.3 13.6 14.0 - 14.4 14.7 15.2 - 15.6 16.0 16.5 - 16.7 17.1 17.6 - 17.7 18.2 18.8 - 18.8 19.2 19.9 -
HI PR 135 145 153 - 151 163 172 - 172 185 195 - 196 211 223 - 220 237 250 - 244 262 277 -
LO PR 56 60 66 - 60 63 69 - 62 66 72 - 65 69 76 - 68 73 79 - 71 75 82 -
MBh 55.31 56.94 61.64 66.15 54.02 55.62 60.20 64.61 52.73 54.30 58.77 63.08 51.45 52.97 57.34 61.54 48.88 50.32 54.47 58.46 45.27 46.61 50.46 54.15
S/T 0.820.740.560.360.850.760.580.370.870.780.590.380.90 0.81 0.61 0.390.940.840.630.410.940.840.640.41
DELTA T21191611211916112119161121 19 16 112119161119181510
2025 KW 3.873.954.064.184.154.234.364.494.394.484.624.764.61 4.70 4.85 5.004.794.895.045.214.955.055.215.38
AMPS 13.9 14.2 14.7 15.2 15.0 15.4 15.9 16.5 16.3 16.7 17.3 17.9 17.4 17.9 18.5 19.2 18.6 19.0 19.7 20.4 19.7 20.2 20.8 21.6
HI PR 142 153 161 168 159 171 181 189 181 195 206 214 206 222 234 244 232 249 263 275 256 276 291 304
LO PR 59 63 69 73 63 67 73 78 65 69 76 81 68 73 80 85 72 76 83 89 74 79 86 92
MBh 53.7 55.3 59.8 64.2 52.4 54.0 58.4 62.7 51.2 52.7 57.1 61.2 50.0
51.4
55.7 59.7 47.5 48.9 52.9 56.8 44.0 45.3 49.0 52.6
S/T 0.780.700.530.340.810.730.550.350.830.750.560.360.86
0.77
0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39
DELTA T22201611222016112220161122
20
17 11 22 20 16 11 20 19 15 11
75 1800 KW 3.843.924.034.154.124.204.324.464.364.454.584.734.57
4.67
4.81 4.96 4.75 4.85 5.00 5.16 4.91 5.01 5.17 5.34
AMPS 13.8 14.1 14.6 15.1 14.9 15.2 15.7 16.3 16.2 16.6 17.1 17.8 17.3
17.7
18.3 19.0 18.4 18.8 19.5 20.2 19.5 20.0 20.6 21.4
HI PR 140 151 160 166 158 170 179 187 179 193 204 212 204
220
232 242 230 247 261 272 254 273 288 301
LO PR 59 63 68 73 62 66 72 77 65 69 75 80 68
72
79 84 71 76 82 88 73 78 85 91
MBh 49.6 51.0 55.2 59.3 48.4 49.8 53.9 57.9 47.3 48.7 52.7 56.5 46.1 47.47 51.4 55.1 43.8 45.1 48.8 52.4 40.6 41.8 45.2 48.5
S/T 0.760.680.510.330.780.700.530.340.800.720.540.350.83 0.74 0.56 0.360.860.770.580.380.870.780.590.38
DELTA T22201711222017122220171222 21 17 122220171121191611
1575 KW 3.763.833.944.064.024.104.234.354.264.344.484.614.46 4.56 4.70 4.844.644.744.885.044.794.895.055.21
AMPS 13.4 13.7 14.2 14.7 14.5 14.8 15.3 15.9 15.7 16.1 16.6 17.3 16.8 17.2 17.8 18.5 17.9 18.3 18.9 19.7 19.0 19.4 20.1 20.8
HI PR 136 147 155 161 153 164 174 181 174 187 197 206 198 213 225 235 223 240 253 264 246 265 280 292
LO PR 57 61 66 71 60 64 70 74 63 67 73 77 66 70 76 81 69 73 80 85 71 76 83 88
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.