GDM-8261 User Manual
92
Recall Measurement Record
Background
The GDM-8261 can recall previously recorded
measurement results for observation and analysis. The
Standard Deviation, Maximum Value, Minimum Value
and Average Value can also be viewed.
Not applicable to
Store/recall measurement history is not applicable to the
Diode/Continuity tests
.
Recall stored
record
Press the Shift key, then the ACI
(Recall) key. The stored
measurement record appears.
ACI
RECALL
1st display
Shows the stored measurement result
2nd display
Shows the reading count
RCL
Indicates the data has been recalled
View each
reading
Change the reading count using the
Up/Down key.
View Max/Min/
Average
Switch to the Standard
Deviation/Average/Maximum/
Minimum value of the recorded data
using the Right key. Use the left key
to go back.