Edit synchronization settings
6. Enter the Gateway address, for example 172.17.123.200.
7. Click Apply.
Edit synchronization settings
It is possible to configure the synchronization between frames.
1. In a web browser, enter the frame's IP address in the address bar.
2. Go to the Settings tab.
3. Under Time Synchronization Settings, define the following parameters:
l
PTP clock type: Select between:
o
Ordinary Boundary: (default) Hybrid between master and slave
o
Slave Only
o
Master Only
l
PTP domain: Enter the PTP domain number
l
Delay mechanism: Select between:
o
PTP: (default) peer to peer
o
E2E: end to end, allows PTP synchronization to work using transparent clocks or non-
PTP-aware networks
4. Click Apply.
Edit fan settings
To change the fan settings for the frame, you must go to the frame's web page.
1. In a web browser, enter the frame's IP address in the address bar.
2. Go to the Settings tab.
3. Select a mode of operation. The modes are named based on their intended use:
l
Silent
l
Office
l
Factory
l
Maximum
4. Click Apply.
- 65 -