EasyManua.ls Logo

HBM ClipX - Page 96

HBM ClipX
248 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation via fieldbus
94
a4643-1.0 HBM: public ClipX
4 11 4 FLOAT RO Field value 0x6100 1
4 12 1 UINT8 RO Scale 1 FV count 0x6120 0
4 13 4 FLOAT RW Scale 1 FV 0x6120 1
4 14 1 UINT8 RO Scale 1 PV count 0x6121 0
4 15 4 FLOAT RW Scale 1 PV 0x6121 1
4 16 1 UINT8 RO Scale 2 FV count 0x6122 0
4 17 4 FLOAT RW Scale 2 FV 0x6122 1
4 18 1 UINT8 RO Scale 2 PV count 0x6123 0
4 19 4 FLOAT RW Scale 2 PV 0x6123 1
4 20 1 UINT8 RO Input offset count 0x6124 0
4 21 4 FLOAT RW Input offset 0x6124 1
4 22 1 UINT8 RO Autozero count 0x6125 0
4 23 4 UINT32 WO Autozero 0x6125 1
4 24 1 UINT8 RO Process value count 0x6130 0
4 25 4 FLOAT RO Process value 0x6130 1
4 26 1 UINT8 RO Tare offset count 0x6138 0
4 27 4 FLOAT RW Tare o ffse t 0x6138 1
4 28 1 UINT8 RO Autotare count 0x6139 0
4 29 4 UINT32 WO Autotare 0x6139 1
4 30 1 UINT8 RO Process net value
count
0x6140 0
4 31 4 FLOAT RO Process net value 0x6140 1
DPV1
No of
bytes
Data
type
R/W Description
ClipX object
directory
Slot Index Index
Sub-
index

Table of Contents

Related product manuals